Owner’s Manual
A NOTE ABOUT SAFETY
Any time you see this symbol in manuals, instructions and on the
unit, be aware of the potential for personal injury. There are three levels
of precaution:
WARNING signifies hazards that could result in personal injury or
death.
CAUTION is used to identify unsafe practices which would result in
minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
ABOUT YOUR HEAT PUMP SYSTEM
Our products are designed, tested and built in accordance with US
Department of Energy standardized procedures and other standards;
however, actual operating results and efficiencies may vary based on
manufacturing and supplier tolerances, equipment configuration,
operating conditions and installation practices.
Identifying Your System
Your new Carrier heat pump system is what we call a “split system”. It
has an outdoor unit and an indoor unit connected to each other with
copper tubing called refrigerant lines. Each of these units has a rating
plate with the model and serial numbers you will need to reference when
calling an authorized Carrier dealer about your system.
Take a few moments now to locate those numbers and record them for
future reference.
Using Your New Carrier System
Your Carrier heat pump system is controlled by a wall-mounted
Infinity® System Control installed inside your home. This system
requires an Infinity® System Control which has software designed
specifically to operate this system. See the Infinity® System
Homeowner Guide for more details on system operation.
Infinity® Variable Speed Operation
You may notice your system runs for longer periods of time. This
system is designed to meet cooling or heating needs of the home at a
wide range of conditions. Your indoor temperature will remain more
consistent with fewer drafts, better humidity control, enhanced comfort
and enhanced energy efficiency.
Heating And Cooling Your Home
For heating or cooling operation, make sure the System or Mode control
is set to the appropriate mode. Then, adjust the Temperature control to
your desired setting. Finally, use the Fan control to select Automatic
(turns on and off as heating is needed) or On (runs continuously).
Depending on your typical heating needs, your home comfort system
may also include a supplementary heating source that will automatically
turn on as needed. You may also select this heat source manually if
desired.
Operation Under Extreme Conditions
Your heat pump will run as long as necessary to maintain the indoor
temperature selected on your Infinity® System Control. On extremely
hot days, your heat pump will run for longer periods at a time than on
moderate days. Your system will also run for longer periods of time
under the following conditions:
• Frequent opening of exterior doors
• Operating laundry appliances
• Operating cooking appliances such as an oven
• Taking hot showers
• More than the usual number of people present in the home
• More than the normal number of electric lights in use
• Drapes or blinds are open on the sunny side of the home
A2L REFRIGERATION DISSIPATION SYSTEM
Your system is utilizing an A2L refrigerant. A2L refrigerants typically
require the installation of a dissipation system on the indoor unit. If a
refrigerant leak is detected, the dissipation system will turn off the
outdoor unit, turn off supplementary heat and turn on the indoor blower.
IMPORTANT HEAT PUMP FACTS
Heat pump systems have a few unique features and operations that you
should be aware of:
• During the heating cycle, your heat pump delivers a constant flow of
air at around 95°F (35°C)to about 105°F (41°C), compared to sudden
blasts of hot air provided by a typical furnace.
• Ice or frost may form on the outdoor coil during winter heating
operation. Your heat pump will automatically melt the ice using its
defrost cycle. During defrost, you may see steam rising from the
outdoor unit or notice the fan has stopped running - both of which are
normal. At the beginning and end of the defrost cycle, you may hear a
“whoosh” sound coming from the unit. This is normal for heat pump
applications.
• Heat pumps installed in areas expecting snow are elevated with
support feet.
• In extreme weather conditions with heavy snow and ice storms,
build-up may accumulate on the top of the heat pump and fan blade,
causing excessive vibration that may result in damage and or reduced
performance. In these conditions, it may be appropriate to turn the
heat pump off and run on auxiliary heat until snow and ice has
cleared.
Sound
Your new heat pump with Greenspeed® Intelligence is different from
most heating and cooling systems. Because this is a variable speed
system, it is designed to operate at different speeds depending on the
temperature and humidity conditions. You may notice the sound coming
from the outdoor unit changing from time to time, and from season to
season. In winter, the system will operate at higher speeds as it gets
colder outside to maintain its heating performance. The higher speed
produces a higher sound. This change of speeds allows the system to
operate more efficiently and maintain comfortable conditions inside the
home. You may also hear a slight “purr” at start-up and shut down.
These sounds are normal and do not represent a problem with your
system.
Infinity® Variable Speed Heat Pump
with Greenspeed® Intelligence
Using Puron Advance™ (R-454B) Refrigerant
WARNING
!
PERSONAL INJURY, DEATH AND / OR PROPERTY
DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Improper installation, adjustment, alteration, service, maintenance, or
use can cause explosion, fire, electrical shock, or other conditions
which may cause personal injury or property damage. Consult a
qualified installer, service agency, or your distributor or branch for
information or assistance. The qualified installer or service agency
must use factory-authorized kits or accessories when modifying this
product.
Read and follow all instructions and warnings, including labels shipped
with or attached to unit before operating your new heat pump.
Probleemoplossing Carrier Infinity 27VNA0