LOCK MODES
A maximum of two users can exist in a lock. A lock can operate in either Single Mode or
Dual Custody Mode.
Note:
For a UL listed installation, only one user can be activated.
• Single Mode E
Single Mode defaults to having only a Manager User (User 1) in the lock. A second
user (User 2) can then be added by the Manager User (User 1). (See section on
Manager User Operations.)
In Single Mode only one valid user combination is required to open the lock - the Manager
User (User 1) combination or the User 2 combination.
Note:
Default lock status from the factory is Single Mode with an opening
combination of “502550” for the Manager User (User 1).
• Dual Custody Mode E E
Dual Custody Mode defaults to two users in the lock - User 1 and User 2.
Two user combinations are required to open the lock - the User 1 combination and the
User 2 combination.
Note:
Manager User Operations are not available in Dual Custody Mode.
LOCK OPERATING CONVENTIONS
• The power source for the Auditcon 2 Lock Series is PowerStar
TM Technology.
With this technology an internal generator is used to create all necessary power.
Important Note: The lock must be manually powered before each operation by
briskly turning the dial back and forth .
• To clear a combination or keystroke, press the key.
• If the bolt is not retracted within 4-6 seconds after a valid opening combination is
accepted, the lock will “relock”.
Please note the following operational differences based on the type of bolt you have
installed:
• Dead Bolt (Manual Locking) Technology: There is a “Home” position for the dial on
the lock that is directly related to the manual retraction or extension of the bolt. In the
“HOME” position, the lip of the dial will cover the red “open lock” indicator. The dial
must be positioned here on a lock “Open’’ operation before you can successfully open
the lock. The dial must be turned to the right (CW) to retract the bolt and unlock the
lock. The dial must be turned to the left (CCW) to extend the bolt and lock the lock. The
lock may not open if more than a 5 lb. force is applied to the end or side of the bolt.
• Slide Bolt (Auto Locking) Technology: Once a combination has been entered and
accepted, the lock bolt movement works in conjunction with the bolt works of the
container. When the bolt works are disengaged to open the container, the lock bolt will
slide into the “unlocked” or retracted position. Once the bolt works are extended to the
locked position, the lock bolt automatically slides into the “locked” position. The lock will
not open if force is applied to the end or side of the bolt.
AUDITCON® 2 SERIES
MODELS 52 & T52
OPERATING INSTRUCTIONS
Document Number 3056.025 Rev. A2 - 05/05