                                Pagina 1/20
                            
                            
                            
INSTALLATION INSTRUCTIONS
33-00229EF-05
HE105, HE205 
Whole Home Bypass Humidifier
APPLICATION
This kit contains your new HE105 or HE205 Humidifier, 
H6062 Digital Humidity Control and all the accessories 
required for installation. 
How Your Humidifier Works
Your humidifier uses the principle that vapor (evaporated 
water) is created when warm air blows over a water-soaked 
area. As the vapor circulates, the relative humidity rises.
Your humidity control monitors the relative humidity and 
activates the humidifier accordingly. The humidifier has a 
water supply that dispenses water evenly over a humidifier 
pad. The warm dry air from the furnace passes over the 
humidifier pad and picks up the moist air to circulate it 
throughout your home.
Humidified air feels warmer and more comfortable so you 
may be able to lower your thermostat heating setpoint, 
which saves money on your heating fuel bills. The end 
result is that your humidifier gives you a comfortable 
environment that is also energy efficient.
Need Help?
For assistance with this product please visit 
http://honeywellhome.com or call Customer Care toll-free 
at 1-800-468-1502. 
PREPARING FOR THE 
INSTALLATION
Be sure to identify all the required (Table 1) accessories 
(included) and make sure the appropriate tools are 
available before beginning the installation.
Included in the box:
• Humidifier
• H6062 Digital Humidity Control
• Transformer
Canadian “C” models also include:
• 6 in. dia. bypass ducting (24 in.)
• 18 gauge thermostat wire (20 ft.)
• 1/4 in. (6.35 mm) OD feed water tubing (20 ft.)
• 1/2 in. (12.7 mm) ID drain tubing (10 ft.)
• Saddle valve
Required Tools
Tools required for installation include:
• Tin snip
• Screwdriver
• Pliers
• Adjustable or open-end wrench
• Drill
• Level
• 3/4 in. (19 mm) sheet metal drill bit
SPECIFICATIONS
Model specific specifications are shown in Table 1.
Operating Ambient Temperature
: 
41 to 113 °F (5 to 45 °C)
Power Supply: 24 VAC / 60 Hz.
Power Consumption: 7 Watts with 24 Vrms
Water Pressure: 40 to 120 psi.
Orifice Output: .02 in. (0.5 mm)
Flow Rate at Nozzle: 4.7 GPH (18 L/hr.) under 120 psi
M36294A
Table 1. Specifications.
Model
Size
length × width × depth
Duct Opening
H × W Pad Size
Evaporation 
Output
HE105 15.16 × 16.57 × 9.47 in.
(385 × 421 × 240 mm)
9.43 × 9.28 in.
(240 × 236 mm)
10 × 9.5 × 1.5 in.
(254 × 241 × 38.1 mm) 12 GPD
HE205 18.30 × 17.11 × 9.59 in.
(465 × 434 × 243 mm)
12.63 × 9.68 in.
(321 × 246 mm)
13.125 × 10 × 1.5 in.
(333 × 254 × 38.1 mm) 17 GPD